Operation
139
The operation of each unit is configured in software and is implemented in
the card through software download messages. When the OPS analog
line card unit is idle, it provides a ground on the tip lead and – 48 V dc on
the ring lead. The on-hook telephone presents a high impedance toward
the line interface unit on the card.
The applications, features, and signaling arrangements for each unit on
the NT1R20 OPS Analog Line Card are assigned through the Single-line
Telephone Administration program LD 10 and/or jumper strap settings on
the card.
The operation of each unit is configured in software and implemented in
the card through software download messages. When the NT1R20 OPS
Analog Line Card unit is idle, it provides a ground on the tip lead and –48
V dc on the ring lead. The on-hook telephone presents a high impedance
toward the line interface unit on the card.
Incoming calls
Incoming calls to a telephone connected to the NT1R20 OPS analog line
card originate from stations that can be local (served by the PBX) or remote
(served through the public switched telephone network). The alerting
signal to telephones is 20 Hz (nominal) ringing. When an incoming call
is answered, ringing is tripped as the telephone goes off-hook, placing
a low-resistance dc loop across the tip and ring leads toward the OPS
analog line card. (see
).
Table 68
Call connection sequence-near-end station receiving call
State
Signal / Direction
Far-end / Near-end
Remarks
Line card unit idle
Group on tip, battery on ring High
resistance loop
No battery current drawn.
Far-end station goes off-hook and
addresses (dials-up) the near-end station.
The system receives the incoming call on a
trunk and determine the TN.
Incoming call
Ringing
The system applies 20 Hz ringing to ring
lead.
Near-end station
off-hook
Low resistance loop
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.