Nortel Networks 311 사용자 설명서

다운로드
페이지 1134
302
NT5D33 and NT5D34 Lineside E1 Interface cards
Figure 66
Set Simple (S S) no screen
Figure 67
Set Simple (S S) yes screen
Set Mode
At the
SET MODE (S M)
command, the MMI prompts the user with the
current signaling mode, either Default (Australian P2) or Table (of bit values.)
Entering a
<CR>
accepts the current value, or the user can type in 1 to
revert to the Default, or 2 to edit the table entries. See
. If the user selects default, then the A/B Bit values is
reset to the Default values.
Responding to the MMI’s Set Mode prompt with "1" also results in the
line, "Signaling Bits set to Default," as in
Figure 68
Set Mode screen
However, responding to this prompt with selects "Table" and allows the
user to set the A/B Bit Mode to whatever configuration the user chooses.
If "Table" is selected, the individual table values are prompted for. See
and
. After each value is displayed, enter
<CR>
to do the following:
accept the current value
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.