Engineering guidelines
397
The MSDL card addresses are set using decimal switches located on the
card. These switches can select 100 unique card addresses from 0 to 99.
An address conflict may occur between the MSDL and other cards because
of truncated address decoding by the other cards. For example, if a DCHI
port is set to address 5, it’s companion port is set to address 4, which means
that none of the MSDL cards can have hexadecimal address numbers 05H,
15H, É75H, nor addresses 04H, 14H, É74H. To avoid this conflicts system
software limits the MSDL card addresses from 0 to 15.
Port specifications
The MSDL card provides four programmable serial ports configured with
software as well as with switches for the following modes of operation:
Transmission mode Configure an MSDL port for synchronous or
asynchronous data transmission using LD 17.
Synchronous transmission uses an external clock signal fed into the MSDL.
lists the
synchronous interface specifications and the means of configuring the
interface parameters.
Table 170
Synchronous interface specifications
Parameter
Specification
Configured
Data bits
In packets-Transparent
N/A
Data rate
1.2, 2.4, 4.8, 9.6, 19.2, 38.4,
48, 56, and 64 kbps
Software
Transmission
Full Duplex
N/A
Clock
Internal/External
Software
Interface
RS-232
Software
RS-422
Switches
Mode
DTE or DCE
Switches
Asynchronous transmission uses an internal clock to generate the
appropriate baud rate for serial controllers.
lists
asynchronous interface specifications and the means of configuring
interface parameters.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008