Nortel Networks 311 사용자 설명서

다운로드
페이지 1134
Applications
795
Port B pads
E and M Trunk Pads
Port-to-port loss (dB)
Port B
Transmit
D to A
Receive
A to D
Transmit
D to A
Receive
A to D
Port B to
E and M
E and M to
Port B
PE CO/FX/W
ATS (TRC)
Out
Out
In
In
0
0
PE tie
Out
Out
In
In
0
0
Note: Transmit and receive designations are from and to the CS 1000. Transmit is from the CS
1000 to the external facility (digital-to-analog direction in the E and M Trunk card). Receive is to the
CS 1000 from the external facility (analog-to-digital direction in the E and M Trunk card).
Figure 258
Pad orientation
Applications
The optional applications, features and signaling arrangements for each
trunk are assigned through unique route and trunk data blocks. Refer to
Features and Services (NN43001-106-B) for information about assigning
features and services to trunks.
The optional applications, features and signaling arrangements for each
trunk are assigned through unique route and trunk data blocks. Refer to
Features and Services (NN43001-106-B) for information about assigning
features and services to trunks.
PAD switching
The transmission properties of each trunk are characterized by
class-of-service (COS) assignments in the trunk data block (LD 14). The
assignment may be non-Via Net Loss (non-VNL) or via Net Loss (VNL). To
ensure stability and minimize echo when connecting to long-haul VNL (Tie)
trunks, non-VNL trunks are assigned either Transmission Compensated
(TRC) or Non-Transmission Compensated (NTC) class-of-service.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.