NT8D41AA Serial Data Interface Paddle Board
Once the board has been installed, the system software must be configured
to recognize it. Instructions for doing this are found in
".
Option switch settings
Address
Address select switch SW4 and logic on the card always address the two
UARTs using a pair of addresses: 0 and 1, 2 and 3 through 15 and 16. The
settings for this switch are shown in
Table 312
SDI paddle board address switch settings
Address
Switch SW4
Port 1
Port 2
1
2
3
4
0
1
off
on
on
on
2
3
off
on
on
off
4
5
off
on
off
on
6
7
off
on
off
off
8
9
off
off
on
on
10
11
off
off
on
off
12
13
off
off
off
on
14
15
off
off
off
off
Baud rate
Switches SW2 and SW3 determine the baud rate for each individual port.
The settings for these switches are shown in
.
Table 313
SDI paddle board baud rate switch settings
Port 1 - SW2
Port 2 - SW3
Baud
rate
1
2
3
4
1
2
3
4
150
off
off
on
on
off
off
on
on
300
off
on
off
on
off
on
off
on
600
off
off
off
on
off
off
off
on
1200
off
on
on
off
off
on
on
off
2400
off
off
on
off
off
off
on
off
4800
off
on
off
off
off
on
off
off
9600
off
off
off
off
off
off
off
off