Physical description
931
Table 384
Switch SW2
Cable Type
SW 2-1
SW 2-2
75 ohms
Up (Off)
Down (On)
120 ohms
Down (On)
Up (Off)
Switch SW3 - Clock Controller Configuration
This switch enables/disables (H/W) the on-board Clock Controller. Disable
the SW 3-2 if the on-board clock controller is not in use.
Table 385
Switch SW3
Switch
Down (On)
Up (Off)
Note
SW 3-1
Spare
SW 3-2
Disabled
Enabled
Switch SW4 - Carrier Shield Grounding
This switch enables for the selective grounding of the Tx / Rx pairs of the
carrier cable. Closing the switch (down position) applies Frame Ground
(FGND) to the coaxial carrier cable shield, creating a 75 ohms unbalanced
configuration. This applies only to the NTBK05CA cable.
Table 386
Switch SW4
Switch
Down (On)
Up (Off)
SW 4-1
Rx – FGND
Rx – OPEN
SW 4-2
Tx – FGND
Tx – OPEN
Note: The usual method is to ground the outer conductor of the receive
coaxial signal.
Power requirements
The NTAK79 obtains its power from the backplane, drawing maximums of 2
A on +5 V, 50 mA on +12 V and 50 mA on –12 V.
The NTAK79 obtains its power from the backplane, drawing maximums of 2
amps on +5 V, 50 mA on +12 V and 50 mA on -12 V.
The NTAK79 obtains its power from the backplane, drawing maximums of 2
A on +5 V, 50 mA on +12 V and 50 mA on –12 V.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.