Nortel Networks 311 사용자 설명서

다운로드
페이지 1134
96
Option settings
NT8D17 Conference/TDS card
Switch and jumper settings are used to select the companding law and to
change the conference attenuation PAD levels. These PAD levels are used
if prompt CPAD = 1 in LD97. The J1 connector on the faceplate is reserved
for future use.
You can enable or disable a warning tone for conference calls. When the
option is enabled, the tone lets callers know they are entering a conference
call. The switch for this option is preset to disable the warning tone.
Companding law
Jumper at J3
µ
-law (North America), A-law
connect pins 2 and 3
Special cases
connect pins 1 and 2
SW2 (see Note)
Attenuation levels
1
2
3
10.2 db
on
on
on
8.5 db
on
off
on
6 db
off
on
on
6 db
off
off
on
4.5 db
on
on
off
3 db
on
off
off
0 db
off
on
off
0 db
off
off
off
Note: Set position 4 to ON to disable the warning tone option. When the warning tone is enabled,
select the warning tone level as shown below.
Level
Jumper at J2
24 db
connect pins 1 and 2
30 db
connect pins 2 and 3
NT8D21 Ringing Generator AC
Settings
Frequency
Amplitude
P1
P2
P3
20 Hz
86 V ac
open
open
2–5
8–11
25 Hz
70 V ac
open
1–4
7–10
open
25 Hz
80 V ac
open
3–6
9–12
open
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008