Maxon Telecom MM-6280IND 사용자 설명서

다운로드
페이지 70
 
 
Extended AT Commands Manual 
Page 15 of 70 
2009-06-25 
Special: Set command 
Command  TE2 
Æ
 
MT2 
$$Connect_Baud=<value> 
Response 
TE2 
Å
 
MT2 
$$ Connect_Baud = <value> 
<result_code> (OK | ERROR) 
 
1: Modem displays baud rate set by +IPR command 
together with Connect message after a circuit switched 
connection is established. E.g. If IPR is set to 19200, the 
connect message should display Connect 19200. 
 
0: Displays only connect message. In this case the 
modem only display Connect after a circuit switched 
connection is established. 
3.4.  IO Functions 
To Change the IO functions of the modem use the AT$$IO_FUNCTION command 
Table 3-6 Read command 
Command  TE2 
Æ
 
MT2 
$$IO_FUNCTION? 
Response 
TE2 
Å
 
MT2 $$IO_FUNCTION: 
<value> 
Table 3-7 Set command 
Command  TE2 
Æ
 
MT2 
$$IO_FUNCTION =<value> 
Value 
0, Disable IO_Function  
1, Activate SMSIO Functions (Default Value) 
2,  Data State Report functions 
 
A. 
Serial 1(DCD Pin) Pin is high. In connection state 
 
B. 
Serial 1(DCD Pin) is low on disconnection state 
3.5.  AT Notification Options 
MT2 will send all notification/notify commands including SMS to TE2 as determined by the 
$$NOTIFCNT value. 
Notification count (AT$$NOTIFCNT) 
Table 3-8 Read command 
Command  TE2 
Æ
 
MT2 
$$NOTIFCNT? 
Response 
TE2 
Å
 
MT2 $$NOTIFCNT: 
<value>