4.1
Jumpers
Notes: 1.
These jumpers are provided for power consumption measurement. By default, they are 
closed. To use this feature, the user has to open the strap and insert an ammeter.
Table 4-1.  Jumpers Configuration
Designation
Default Setting
Feature
J2
Closed
3.3V Jumper
J3
Closed
Forces power on.
To use the software shutdown control, J3 must be opened. 3V 
battery backup must be present.
J6
Closed
VDDPLL Jumper
J7
2-3
Erase/Normal operation mode
1-2: Erase entire flash chip
2-3 or open: Normal operating mode
J9
2 - 3
Slow Clock OSCSEL
 
1-2: Internal RC Oscillator
 
2-3: External Crystal Oscillator
J10
Closed
VDDBU Jumper
J12
Closed
VDDCORE Jumper
J15
Closed
Enables Ethernet Auto MDIX control
J32
Closed
Enables the use of the embedded NANDFLASH device (MN6xx)
J33
Closed
Enables the use of the embedded DATAFLASH device (MN9)