Enterasys Networks 1G58x-09 사용자 설명서

다운로드
페이지 808
Process Overview: Routing Protocol Configuration
Configuring IRDP
13-70
Example
This example shows how to set the maximum IRDP advertisement interval to 1000 seconds on 
VLAN 1:
13.1.4.3 ip irdp minadvertinterval
Use this command to set the minimum interval in seconds between IRDP advertisements.
ip irdp minadvertinterval interval
Syntax Description
Command Syntax of the “no” Form
The “no” form of this command deletes the custom holdtime setting and resets the 
minimum advertisement interval to the default value of three-fourths of the 
maxadvertinterval 
value: 
no irdp minadvertinterval
Command Type
Router command.
Command Mode
Interface configuration: Matrix>Router(config-if(Vlan <vlan_id>))#
Command Defaults
None.
Example
This example shows how to set the minimum IRDP advertisement interval to 500 seconds on 
VLAN 1:
Matrix>Router(config)#interface vlan 1
Matrix>Router(config-if(Vlan 1))#ip irdp maxadvertinterval 1000
interval
Specifies a minimum advertisement interval in seconds. 
Valid values are to 1800.
Matrix>Router(config)#interface vlan 1
Matrix>Router(config-if(Vlan 1))#ip irdp minadvertinterval 500