Schneider Electric 17S Series 사용자 설명서

다운로드
페이지 146
85
Environmental and Mechanical Specifications
Environmental 
Specifications 
Table
The following table provides 17S environmental specifications.
Continued on next page
ENVIRONMENTAL
Storage
High temperature, 
non–operating
+70
°
C maximum
Low temperature, 
non–operating
–25
°
C minimum
Humidity
Non–operating
95% RH maximum,
non-condensing 
Operating
85% RH maximum,
non-condensing
Operating temperature   
(ambient measured at fan inlet)
Full power
With linear derating
2,5% / °C
(available power: 75% of 
rated output at 55
°
C)
0 ... 45
°
C
45 ... 55°C max
Vibration (operational)
10 ... 57 Hz
Sinusoidal, 0.75 mm 
amplitude
57 ... 150 Hz
1.0 g
Air pressure
Operating:
Full power
With linear derating
1,5% / 100m
(available power: 75% 
of rated output at 
2500m)
1000 m (90 kPa)
1000 ... 2500m (73kPa) max 
Transport
57 kPa (4540 m)
Contaminants
Pollution degree 2, as defined in EN60204/EN50178
Cooling
Models:
MHDS1004N00
MHDS1008N00
MHDS1017N00
MHDS1028N00
MHDS1056N00
Integrated heatsink with 
internal fan.