Zebra Technologies 105S 사용자 설명서

다운로드
페이지 110
Zebra S-Series User’s Guide
9
Figure 1
$&3RZHU)XVH5HSODFHPHQW
A user-replaceable AC power fuse is located just above the power         
ON/OFF switch (see Figure 1).  For a 115 VAC installation, the 
replacement fuse is a 3AG Fast Blow style rated at 5 Amp/250VAC.  For a 
230 VAC installation, the fuse is the same style but rated at 3 Amp/250 
VAC.  Make sure the fuse you use is correct for the voltage source.
Note:   Before replacing the fuse, turn the AC power switch OFF and 
unplug the AC power cable.
1. To replace the fuse, insert the tip of a flatblade screwdriver into the 
slot in the end of the fuse holder end cap.  
2. Press in slightly on the end cap and turn the screwdriver slightly 
counterclockwise.  This disengages the end cap from the fuse holder 
and allows you to remove the fuse.  
3. To install a new fuse, remove the old fuse and insert the new fuse into 
the fuse holder.
4. Push the end cap in slightly, then insert the tip of a flatblade 
screwdriver into the slot in the end cap and turn clockwise to engage it.