Enterasys Networks 4G4282-49 사용자 설명서

다운로드
페이지 90
10BASE-T Network
2-2 Network Requirements
In normal usage (and typical implementations) there is no need to enable/disable ports for 
Link Aggregation. The default values will result in the maximum number of aggregations 
possible. If the switch is placed in a configuration with its peers not running the protocol, 
no aggregations will be formed and the modules will function normally (that is, Spanning 
Tree will block redundant paths).
For details about the commands involved with configuring the Link Aggregation 
function, refer to the Matrix DFE‐Gold Series Configuration Guide.
10BASE-T Network 
When connecting a 10BASE‐T segment to any of the fixed front panel ports of the 
4G4202‐72 or 4G4282‐49, ensure that the network meets the Ethernet network 
requirements of the IEEE 802.3‐2002 standard for 10BASE‐T. Refer to the Cabling Guide for 
details.
100BASE-TX Network
The fixed front panel ports of the 4G4202‐72 or 4G4282‐49 provide a connection that 
supports Category 5 UTP cabling. The device at the other end of the twisted pair segment 
must meet IEEE 802.3‐2002 100BASE‐TX Fast Ethernet network requirements for the 
devices to operate at 100 Mbps. Refer to the Cabling Guide for details.
1000BASE-SX/LX/ELX Network 
The optional Mini‐GBICs provide a Gigabit Ethernet connection to the optional 
7G‐6MGBIC‐A interface module to provide fiber‐optic connections operating at 
1000 Mbps (1 Gbps). Other Mini‐GBICs may support different types of cabling 
connections. The device at the other end of the fiber‐optic connection must meet IEEE 
802.3‐2002 Gigabit Ethernet requirements for the devices to operate at Gigabit speed. 
Refer to 
 for further details on Mini‐GBIC specifications. 
Note: If a port is to operate at 100 Mbps, Category 5 cabling must be used. Category 3 
cabling does not meet 100 Mbps specifications. For 10 Mbps operation only, Category 3 
or Category 5 cabling can be used. Refer to 
information about 100BASE-TX networks and cabling.
Note: The fixed ports of the module support Category 5 UTP cabling with an impedance 
between 85 and 111 ohms for 100 Mbps operation. The module is capable of operating at 
10, 100, or 1000 Mbps and can automatically sense the port speed of the other device and 
adjust its speed accordingly.