Enterasys Networks 4G4282-49 사용자 설명서
COM Port Pinout Assignments
Matrix DFE-Gold Series Installation Guide A-7
COM Port Pinout Assignments
The COM port is a serial communications port for access to Local Management. Refer to
Regulatory Compliance
The 4G4202‐72 and 4G4282‐49 meet the safety and electromagnetic compatibility (EMC)
requirements listed in
requirements listed in
Table A-13 COM Port Pin Assignments
Pin
Signal Name
Input/Output
1
Transmit Data (XMT)
Output
2
Clear to Send (CTS)
Input
3
Data Set Ready (DSR)
Input
4
Receive Data (RCV)
Input
5
Signal Ground (GND)
NA
6
Request to Send (RTS)
Output
7
Data Terminal Ready (DTR)
Output
8
Data Carrier Detect (DCD)
Input
Table A-14 Compliance Standards
Regulatory Compliance
Standards
Safety
UL 60950, CSA C22.2 No. 60950, 2006/95/EC, EN 60950,
IEC 60950, EN 60825, 21 CFR 1040.10.
IEC 60950, EN 60825, 21 CFR 1040.10.
Electromagnetic Compatibility
(EMC)
(EMC)
47 CFR Parts 2 and 15, CSA C108.8, 2004/108/EC, EN
55022, EN 61000-3-2, EN 61000-3-3, EN 55024, AS/NZS
CISPR 22, VCCI V-3.
55022, EN 61000-3-2, EN 61000-3-3, EN 55024, AS/NZS
CISPR 22, VCCI V-3.