Asante Technologies 8000 사용자 설명서

다운로드
페이지 168
Installation and Setup
Page 2-12
2
When the IntraCore 8000 is connected to the network and 
is powered on, it automatically transmits a BootP request 
across the network (up to 10 times) until it receives a 
valid IP address from the BootP server.
3
After an IP address is received, the IntraCore 8000 can be 
managed via in-band access. For more information, see 
Chapter 3, “Configuration.”
To verify that a valid IP address was received, try to ‘ping’ the IntraCore 
8000. If you can access the IntraCore 8000, it is properly configured with an 
IP address.
For more information on using BootP, see “Bootstrap Configuration” i
Chapter 3.
Connecting To a Console
To make the cable connection from a terminal to the console port of the 
IntraCore 8000, use the following procedure.
1
Using a straight-through RS-232 cable with a 9-pin male 
D-subminiature plug at one end, connect a terminal or 
workstation (PC or Macintosh) running a terminal emula-
tor to the console port on the front of the IntraCore 8000.
2
Make sure both units are powered on.
If using a PC with a terminal emulator, make sure it is 
configured with the following terminal settings:
G  Baud:  9600 
G  Data Bits:  8
G  Parity:  None
G  Stop Bits:  1
G  Flow Control:  None
3
Once connected, the Local Management Main Menu 
appears on the terminal screen. 
For further information on setting an IP address for configuration of a 
terminal, or a PC running a VT100 terminal or emulator (such as 
HyperTerminal, ProComm, or ZTerm), see “System IP Configuration” i
Chapter 3.