Fujitsu RX330 사용자 설명서

다운로드
페이지 94
RX330 S1
Operating manual
35
Hardware installation
Installing/removing the server in/from the rack
4.2
Installing/removing the server in/from the 
rack
V
CAUTION!
Follow the safety instructions in chapter 
 and section 
At least two people are needed to position the server into/out of 
the rack.
The rack can tip over when more than one unit is removed.
The server may not occupy the top height unit of the rack (38 HU/42 
HU PRIMECENTER Rack and/or DataCenter Rack), as otherwise 
boards or fans cannot be replaced even with the plug-in module fully 
extended.
Rack requirements
The rack systems from Fujitsu Siemens Computers (PRIMECENTER Rack and 
DataCenter Rack) support installation of PRIMERGY servers. Installation in 
most current rack systems from other manufacturers (3rd party racks) is also 
supported.
To accommodate the ventilation concept and ensure proper ventilation, any 
unused areas in the rack must be sealed using dummy covers.
The power is supplied via the multiple socket outlets fitted in the rack.