7
7.5.2 Installable Expansion Cards and Notes on 
Installation 
■ Installable Expansion Cards
Up to five expansion cards listed on the following table can be installed in the server.
■ Order of Expansion Card Installation
Install expansion cards into the slots in accordance with the priority indicated in the following table.
 Follow the "Installation order" shown in the table when installing the cards and drivers. If you turn on 
the power after installing multiple expansion cards simultaneously or in a wrong order, they will not 
function properly.
table: List of Installable Expansion Cards 
Installable card (Model name)
Number 
of cards
Remarks 
Remote Service Board (PG-RSB103)
1
1
RAID Ctrl 0-Channel 128MB w/ BBU 
(PG-140D1) 
1
1
For internal array system
(Ultra 320 0ch SCSI)
RAID Ctrl 2-Channel 128MB w/ BBU 
(PG-142E3)
2
4
For internal/external array systems
 (Ultra 320 2ch SCSI)
SCSI Ctrl U160 (PG-128)
2
For internal/external SCSI devices
(Ultra 160 SCSI)
Fibre Channel Controller (PG-FC106)
2
Eth. Ctrl 1000-BASE-T Cu (PG-1892)
4
4
1000BASE-T
Eth. Ctrl 1000-BASE-SX Fibre LC (PG-1882)
2
1000BASE-SX
Eth. Ctrl 1000-BASE-T Cu (PG-1852)
3
1000BASE-T
Eth. Ctrl 2x1000-BASE-T Cu (PG-1862)
2
1000BASE-T
table: Expansion Card Installation Order and Slots
Installable expansion card (Model name)
PCI slot 
Installation 
order
1
2
3
4
5
Remote service board (PG-RSB103)
-
-
-
-
1
1
RAID Ctrl 0-Channel 128MB w/ BBU (PG-140D1) 
1
-
-
-
-
2
RAID Ctrl 2-Channel 128MB w/ BBU (PG-142E3) 
1
2
3
4
-
3
SCSI Ctrl U160 (PG-128)
1
2
3
4
-
4
Fibre Channel Controller (GP-FC106) 
3
4
1
2
-
5
Eth. Ctrl 1000-BASE-T Cu (PG-1892)
3
4
1
2
-
6
Eth. Ctrl 1000-BASE-SX Fibre LC (PG-1882)
3
4
1
2
-
7
Eth. Ctrl 1000-BASE-T Cu (PG-1852)
2
3
4
5
1
8
Eth. Ctrl 2x1000-BASE-T Cu (PG-1862)
3
4
1
2
-
9