Datalogic Scanning 4410 사용자 설명서

다운로드
페이지 240
Bar Code Parameters
Product Reference Guide
F-9
Read Veri-
fication
Sets the number of times a label 
must be read before it is transmit-
ted.
0
4
2
6
01 - 04
01
02
01
9
User ID
Specifies the symbology identifier 
(if any) sent when parameter Send 
Code ID (Index 0025) is set to 3. 
 code zero (null) is used to 
indicate that an identifier is not to 
be sent for the symbology.
0
4
2
7
Any 
single 
ASCII 
charac-
ter
(00 = 
Off)
'K'
'K'
'K'
9
9
European Article Numbering-13 
(EAN-13)
Enter 1 for On 
and 0 for Off.
Enable
Enables/disables the EAN-13 sym-
bology.
0
5
1
0
On or 
Off
Off
On
On
9
9
Enable 
Aggres-
sive 
Decoding
Enables more aggressive decoding 
algorithms to be used in order to 
scan hard to read labels.
0
5
1
1
On or 
Off
Off
On
Off
9
Send 
Check 
Digit
Includes a check digit in the label 
which is transmitted.
0
5
1
2
On or 
Off
Off
On
Off
9
9
Send Sys-
tem Digit
This instructs the decoder to 
include the system digit in the label 
transmission. For UPC-E, the sys-
tem digit is zero. 
0
5
1
3
On or 
Off
Off
On
On
9
Code Parameter/ Description
I.
D. 
#
Accep-
table 
Input
Defaults
Scanner Type
Min
Max
Fac-
tory
Laser/
Linear 
Imager
2D 
Imag