Datalogic Scanning 4410 사용자 설명서

다운로드
페이지 240
Programming Parameters
F-32
Falcon
® 
4400 Series with Windows
®
 CE
Table F-4. Imaging Controls
Code Parameter/ Description
I.
D. 
#
Accep-
table 
Input
Defaults
Min
Max
Factory
Imaging Controls
Enter 1 for On and 0 for Off.
Imager Illu-
minate 
Enable
Instructs the PDT to illuminate the scanning 
area (independent of any targeting beam) 
when using an imager.
0
0
0
8
On or 
Off
On
On
On
Imager Aim 
Mode
Toggles between two different operating 
modes for the targeting beam: 
Concurrent (Off): The targeting beam is 
turned on at the same time as an enabled 
illumination beam. 
Interlaced (On): Toggles the aimer and illu-
mination beam.
0
0
0
9
On or 
Off
On
On
On
Imager Aim 
Enable
Instructs the PDT to make use of a target-
ing beam when an imager is installed
0
0
0
A
On or 
Off
On
On
On
Image LED 
Enable
Instructs the imager to use LED illumination 
when taking images.
0
C
0
8
On or 
Off
Off
Off
Off
Image LR Fil-
ter Enable
Instructs the imager to use a filter that 
improves the quality of images taken at 
longer distances.
0
C
0
9
On or 
Off
Off
Off
Off
Imaging 
Width
Specifies the width of images taken with an 
imager
0
C
2
3
1 to 640 
(in pix-
els)
640
640
640
Imaging 
Height
Specifies the height of images taken with 
an imager.
0
C
2
4
1 to 480 
(in pix-
els)
480
480
480