Sony PCS-G70P 사용자 설명서
PCS-G70/G70P
3-863-237-11 (1)
Y:\04C08060_passage\EDIT\10OTH.FM
masterpage:Left
207
Troubleshooting
Troubleshooting
If the Communication Terminal does not function correctly, check the following.
Symptom
Cause
Solution
The power is not
turned on.
turned on.
The power switch is not set to on.
Set the power switch to on (
@
The batteries in the Remote
Commander are low or dead.
Commander are low or dead.
Replace the batteries with new ones
(page 25).
(page 25).
Three indicators on
the front of the
Communication
Terminal blink.
the front of the
Communication
Terminal blink.
The fan inside the terminal stops.
Turn off the system immediately and
consult with Sony dealer.
consult with Sony dealer.
No sound or the
volume is very low.
volume is very low.
The volume of the system is too
low.
low.
The volume of the TV monitor is
too low.
too low.
Adjust the volume of the TV monitor.
The microphone on the remote
party is turned off.
party is turned off.
Ask the remote party to turn on the
microphone.
microphone.
“Mic Select” is not set properly.
Audio input is not selected
properly.
properly.
Set up “Input Select” properly (page
50).
50).
The microphone or external
equipment is not connected
correctly.
equipment is not connected
correctly.
Picture is blurred.
Manual focus is selected but picture
remains blurred.
remains blurred.
Adjust the focus (page 95).
When auto focus is selected, the
background is too bright, contrast is
too high, or the background or the
participants’ clothes contain fine
line patterns.
background is too bright, contrast is
too high, or the background or the
participants’ clothes contain fine
line patterns.
Select manual focus and adjust
manually (page 96).