Franke Consumer Products FDF 9044 I XS ECS 사용자 설명서

다운로드
페이지 68
 
 
 
 
EN 
 
1
5
 
15 
MAINTENANCE
 
Grease filters 
CLEANING METAL SELF- SUPPORTING GREASE FILTERS 
•  The filters must be cleaned every 2 months of operation, or 
more frequently for particularly heavy usage, and can be 
washed in a dishwasher. 
•  Remove the filters one at a time holding them up with one 
hand and pulling the handle downwards with the other hand at 
the same time. 
•  Wash the filters, taking care not to bend them. Allow them to 
dry before refitting. 
•  When refitting the filters, make sure that the handle is visible 
on the outside.
 
 
Activated charcoal filter (Recirculation version) 
REPLACING THE ACTIVATED CHARCOAL FILTER 
•  The filter is not washable and cannot be regenerated, and 
must be replaced approximately every 4 months of opera-
tion, or more frequently for particularly heavy usage. 
•  Remove the metal grease filters 
•  Remove the saturated activated carbon filter by releasing the 
fixing hooks 
•  Fit the new filter by hooking it into its seating 
•  Replace the metal grease filters.
 
 
Lighting 
LIGHT REPLACEMENT 
20 W halogen light. 
•  Remove the 2 screws fixing the Lighting support, and pull it 
out of from the Hood. 
•  Extract the lamp from the Support. 
•  Replace with another of the same type, making sure that the 
two pins are properly inserted in the lamp holder socket holes. 
•  Replace the Support, fixing it in place with the two screws re-
moved as above.