Mitsubishi Electronics A0567659 사용자 설명서

다운로드
페이지 96
Gravimetric Batch Blenders w/Mitsubishi Control      Chapter 5: Maintenance 
70 
Pneumatic System Maintenance 
The Slide Gate/Auger blending system uses plant-supplied compressed air to operate the 
metering and dump valves on the blender. 
It is the user’s responsibility to provide CLEAN AND DRY air for the blender to be 
connected to. The air supply should be filtered through a 5 micron air filter and have a water 
separator installed. Oil should not be used unless air dryers are installed on the compressed 
air supply.  In this case, an oiler may be required on the blender to keep the air cylinder seals 
lubricated. 
Note: 
As this blender uses air for blender metering functions, it is very important to 
supply clean, dry air to the blender. Dirty air can affect blender accuracy, 
result in poor performance and cause injury.  
Provide a 5-micron air filter on 
the air supply to the blender and be sure excess oil is removed. 
If a dirty air filter is noticed during regular inspection intervals, replace with a new 5-micron 
air filter.  Check the compressed air supply and ensure that the necessary steps have been 
taken to remove any oil from the process.    
5 MICRON
 
FILTER
 
DRY 60 psi COMPRESSED AIR
 
LUBRICATOR
 
PRES SURE
 
REGULATOR
 
OS/OA BLENDER
 
CUSTOMER-SUPPLIED COMPRESSED AIR COMPONENTS
 
 
The working pressure of the blender cylinders is 60 psi. This is adjustable by the regulator 
supplied on the rear panel of the blender. (It is important that the air pressure to the blender is 
not fluctuating by installing the unit on an air line with other equipment using large volumes 
of air. If this is the case, an accumulator tank with a check valve may have to be provided by 
the customer to ensure the blender a steady air supply.) 
WARNING!  Always disconnect the compressed air supply when working on any part of 
the blender. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
BLENDER