Page 34
P2608
to advance to the next function screen, or press 
and release either ON/OFF switch located on the 
front switch panel to exit the CALIBRATE FLOW 
function and return to the MAIN SCREEN.
9.  Repeat  steps  1  -  8  when  calibrating  the  other 
side.
NEW L SPRY FLOW
XX.X OZ/M
LEFT OZ  XX.X
(-)        DONE        (+)
CALIBRATE FLOW?
NO                     YES
SPRAYHEAD CAL?
NO                     YES
CONTAINER RDY?
QUIT                   YES
CALIBRATE SPRAY
PRESSBREWSTART
CALIBRATE SPRAY
60 SEC TO FINISH
Left or Right
L or R
COUNTS DOWN
TO ZERO
AFTER 1 MINUTE
BREW PRESSED
EXIT TO THE
NEXT FUNCTION
SCREEN
Procedures to calibrate the bypass flow rate:
1.  Place a container, accurately graduated in ounces, 
and with a minimum capacity of 60 ounces, below 
the funnel on the brewer to be calibrated.
2.  Press and hold the upper right hidden switch until 
the display reads UNITS. Release the switch. Con-
tinue to press and release switch until the display 
reads CALIBRATE FLOW?.
3.  Press and release YES to advance to the SPRAY 
HEAD CAL? function screen. (Pressing NO in the 
CALIBRATE FLOW screen will advance to the next 
function screen, BREW COUNTERS).
4.  Press and release NO to advance to the BYPASS 
CALIBRATION screen.
5.  Press and release YES. The display should read 
CONTAINER READY? If the container is under the 
funnel, press YES. The display should read CALI-
BRATE BYPASS .. PRESS BREW TO START.
6.  Press and release the BREW switch on the side to 
be calibrated. The display should read CALIBRATE 
BYPASS .. 60 SEC TO FINISH. The 60 second timer 
on the display will count down to zero. When the 
counter reaches zero, the display will change to 
LEFT or RIGHT OZ.,  along with a number signify-
ing ounces per minute.
7.  Measure the amount of water in the container, and 
using (-) or (+), adjust the amount on the display 
to match the amount in the container. Then press 
DONE.
8.  The display should now read NEW L or R BYPS 
FLOW, along with the correct flow rate of the by-
pass in ounces per minute. After about 5 seconds, 
the display will return to the CALIBRATE FLOW 
screen.
9.  To exit the CALIBRATE FLOW function, press and 
release NO to advance to next function screen, or 
press and release either ON/OFF switch located on 
the front switch panel to exit the CALIBRATE FLOW 
function and return to the MAIN SCREEN.
10. Repeat  steps  1  -  9  when  calibrating  the  other 
side.
CALIBRATE FLOW (cont.)
PROGRAMMING THE BREWER (cont.)
29877-3 062005