Haier BD-478A 사용자 설명서

다운로드
페이지 61
 
 
 
15
12.1.1 Servicing freezer   
(1)Check the whole circuit of freezer, if there are wire connections 
came off, any wires broken, or a short circuit.   
(2) Check the insulation of the whole freezer. At normal situation, 
the resistance is greater than 2 mebohms; if it is less than 2 
mebohms, please make a further check of the freezer resistance. 
Set the voltmeter to R1 Ohm position, put the two voltmeter leads 
pencils into L and N terminals respectively, watch the indication 
of odometer. The normal value is several Ohm to tens of ohm. If 
the resistance is zero, means that there is a short in the freezer 
circuit or there is a short caused by a bad compressor or fan 
motor. The reason should be found out and repaired. If the 
resistance is too big or infinite, this means that there is broken 
circuit, please check and solve it. 
After the above checks, the freezer will not have any 
electrical problem and you can switch power on for further 
completely check. 
 
MAINTENANCE SERVICE AND TROUBLE SHOOTING
 
Maintenance  Service  and  Trouble  Shooting 
12.1.2 Reasons of electricity leakage of freezer 
PDF created with pdfFactory trial version