several minutes later it starts  again  and stops  automatically  again.  With in 
cycles  like  this  and  the  motor,  or  starter,  and  thermal  protection  unit  will 
burn up  after  a long  time. The main reason is: the motor  coil is shorted at 
some parts. 
Second,  the  freezer  operates  a  certain  time  after  starting,  but  it  will  stop 
automatically  before  the  temperature  reduces  before  the  desired 
temperature  is  reached.  After  several  minutes,  it  will  start  again,  and  the 
electricity  consumption  increases  bad.  The  reason  is  that  the  insulation 
around the motor windings bad. 
12.3 Service and technical requirements of a R134a freezer 
12.3.1 Refrigeration equipment requirements   
The  compressor,  condenser,  evaporator,  drying  filter  must  be  special  for 
R134a freezer and not be confused. 
12.3.2 Repair equipment Requirements 
(1) The evacuation and fill machine is special only for R134a use. 
(2) Other equipment (such as pressure gauge) has no special requirements, 
but once it is used for R134a freezer, it can be no longer for other use. 
MAINTENANCE SERVICE AND TROUBLE SHOOTING
 
Maintenance Service and Trouble Shooting
 
12.3.3 Service procedure     