Fujitsu Kit Conversion PRIMERGY TX300 S5 Tour -> Rack S26361-F2544-L6 사용자 설명서

제품 코드
S26361-F2544-L6
다운로드
페이지 30
System configurator and order-information guide
PRIMERGY TX300 S5           Status 2009-09-29
Configuration diagram PRIMERGY TX300 S5
System unit ( I )
SIDE VIEW
FRONT VIEW
           
3 x 5.25"  bays available
1. PSU
3 x HH  5.25" free 
or 
2 x HH 5,25" free + Option A 
or 
          Hot plug power supply
1 x HH  5.25" free + Option C 
2. PSU
  Redundant power supply option
LSP/LSD Option
Slim CD / DVD
Box 2
Slim CD / DVD
Box 1
   
SAS / SATA
2x
Memory CPU1 
LSP/LSD Option
   1.6 * 5.25"
   
   1.6 * 5.25"
( Channel A + B + C )
not used
SAS / SATA
Bank 1 (3 Modules)
Xeon Dual-or Quad 
Bank 2 (3 Modules)
Core CPU incl. Heatpipe
Bank 3 (3 Modules)
Xeon Dual-or Quad 
     Accessible drives ( V )
Core CPU incl. Heatpipe
Memory CPU2 
Mounting Kit DVD(sl) + LSP/LSD: (
Option A
)
( Channel D + E + F)
- support for SL (0.5") DVD Drive + LSP /LPD
Processor ( II )
(Local Service Panel / Local Service Display)
Bank 1 (3 Modules)
Xeon Dual-or Quad Core
- occupies one 5.25" bay
Bank 2 (3 Modules)
CPU with serial QPI
MtK DVD(sl)+LSP/LSD+SAS LFF HDD: (
Option C
)
Bank 3 (3 Modules)
Interface and 
- support for 
3 memory channels
  
 + 2x 3.5" SAS HDD hot plug
Memory ( III )
 + SL (0.5") DVD Drive
 + LSP / LSD (Local Service Panel / Local Service Display)
LSD / LED Display = Local Service or LED Display
 
   Modular RAID
Raid Card for IME, Raid 0 / 1E
Hard disk drives ( VI )
Support
Raid Card for Raid 5
3.5" SAS / SATA
Extension slots for:
1x 6-port 
  SCSI / SAS Controller for backup( VII )
SAS backplane
SAS Disk Array ( VIII )
Communication/Network ( IX )
Miscellaneous ( X )
1 * 3.5" SAS / SATA 
Slot 7 PCIe-2 x8 (wired x8), notched, 250mm
1 * 3.5" SAS / SATA 
Possible to plug x16 cards
Slot 6 PCIe-2 x8 (wired x8), notched, 250mm
1 * 3.5" SAS / SATA 
Possible to plug x16 cards
Slot 5 PCIe-2 x8 (wired x4), max. 250mm
1 * 3.5" SAS / SATA 
Slot 5 = wired x8 if slot 4 is empty
Slot 4 PCIe-2 x8 (wired x4), max. 250mm
1 * 3.5" SAS / SATA 
Slot 3 PCIe-2 x8 (wired x4), max. 250mm
1 * 3.5" SAS / SATA 
Slot 3 = wired x8 if slot 2 is empty
Slot 2 PCIe-2 x8 (wired x4), max. 250mm
Slot 1 PCIe-2 x8 (wired x4), max. 250mm
internal USB
Reserved for modular RAID-Controller 
or USSD
Key:
Included in basic unit
Option
( LP ready = Slots for low profile boards)
One CPU ( first CPU ) and one memory per CPU ( first memory ) has to be selected for an orderable basic unit.
Slot 3 wired x8
                         ( 3x 120mm Standard Fans; No Redundancy )
FAN 3
FAN 2
FAN 1
Slot 5 wired x8
   1.6 * 5.25"
Air - Channel
FAN 5 + 6
FAN 1+ 2
FAN 3 + 4
   1.6 * 5.25"
   1.6 * 5.25"
Air - Channel
         ( 3x 120mm hot plug Double-Fans; with Redundancy )
Fujitsu Technology Solutions x86  PRIMERGY Server
3 of 30