Instructions for the Installer
 
 
 
 
2.  INSTALLING THE OVEN 
 
 
 
The oven is designed for free-standing installation on a horizontal work-
top. It must be far enough from the wall behind it to allow easy access to 
the terminal board for connection of the power supply lead. Installation 
must be carried out by a 
qualified engineer in compliance with the 
relevant EEC DIRECTIVES. 
 
 
 
2.1  Electrical connection  
 
Check that the power supply voltage and size are as specified on the 
nameplate on the side of the oven. This nameplate must never be 
removed.
 
The oven is fitted with a H07RN-F 
three-core cable for operation at 
240-240V
.  
For operation at 380-415V2N
  or 
380-415V3N
, the power supply 
cable has to be replaced and the 
connection to the terminal board 
modified. The terminal board can 
be accessed by removing the 
panel on the back of the oven. 
 
 
 
 
The power supply lead supplied is of 
H07RN-F type, gauge 3 x 4 mm
2
.  
For operation at 
380-415V2N
  or  380-
415V3N
, the power supply cable has to be 
replaced with one of H07RN-F type. The 
gauge of the wires in the new cable must be 
at least 2.5-1.5 mm
2
 (4 x 2.5 mm
- 5  x 
1.5 mm
2
), bearing in mind that the earth wire 
(yellow-green) must be at least 20 mm 
longer at the end for connection to the oven.
 
 
 