Viper Service Manual                              
Publication Number: 621360041TBSER
- 32 -
© 2010, IMI Cornelius Inc.
BRIX Setup Menu
BRIX is important to the quality of the final product. The BRIX menu facilitates 
the extraction of a sample of product from the unit for BRIX measurement. There 
is an automatic three second dispense of product that produces a constant 
volume so that a BRIX comparison can be made between samples. To perform 
a BRIX test, perform the procedure in Table 27.
DEFROST #1
HHHHH:MM
Shows how long the barrel has been in defrost 
mode
FILL CYCLES #1
########
Shows the number of times the barrel has filled 
with product
SYRUP RUN #1
HH:MM:SS
Shows how long the syrup solenoid has been 
open
SYRUP OUT #1
HHHHH:MM
Shows how long the syrup has been out
ERROR #1
HHHHH:MM
Shows how long the barrel has had an error
Table 26
Display
Value
Description
Table 27
Step
Action
Procedure
1
Set status of barrels
Make sure the status of all barrels is OFF on the con-
trol display.
2
Remove drip tray/access 
panel
Remove the drip tray, loosen the two screws holding 
the access panel and remove it. (Figure 25)
3
Set product supply valve
Turn product supply valve to the 180 degree (BRIX) 
position for the barrel you are testing. (See Figure 26)
4
Access BRIX menu
Press MENU. Then press the SETUP button.
5
Set barrel for BRIX
From the Setup screen (Figure 13), open the BRIX 
Setup screen, shown in Figure 24
6
Use the Up and Down arrows to highlight BRIX 
SETUP. Press the GO button at the bottom of the dis-
play.
7
Select barrel
Use the Up and Down arrows to highlight the desired 
barrel for BRIXing.
8
Perform BRIX procedure
Locate the appropriate barrel sample tube and hold a 
cup under it.
9
Open the valve at the end of the sample tube. Press 
the BRIX button, and wait 3-5 seconds. The product 
pump pumps product for approximately 3 seconds. 
After the sample is dispensed Press BRIX twice 
more to dispense product two more times. Discard all 
three of these samples.
10
Press the BRIX button a fourth time. Collect this sample 
in a cup and close the valve at end of the sample tube.
11
Measure BRIX
Place adequate amount of the product on a refracto-
meter and read the BRIX value. A target BRIX read-
ing of 13.0 (+/- 1.0) is normally desired for sugar-
based syrups. Lower values for some diet syrups can 
be specified. Check with the syrup manufacturer if 
you are not sure.
12
Adjust BRIX
If BRIX is not within the proper range, adjust the 
syrup/water mixture by opening or closing the syrup 
valve, shown in Figure 27, and then retest. 
13
Clear hose
When BRIX measurement is complete, press the 
valve on the bottom of the appropriate water solenoid 
to flush out the hose before closing the valve at the 
end of the hose.
14
Set product supply valve
Turn product supply valve back to the (BARREL) 
position for the barrel you tested. (See Figure 26)