Cornelius 3 사용자 설명서

다운로드
페이지 74
Viper Service Manual                                 
Publication Number: 621360041TBSER
- 60 -
© 2010, IMI Cornelius Inc.
Figure 52. View of Syrup Pressure Switch and  Valve
W
ATER
 P
RESSURE
 S
WITCH
 R
EPLACEMENT
The water pressure switch, shown in Figure 53, is located in back of the water 
filter, when viewed from the rear of the unit. Access to the switch is obtained by 
removing the left side panel of the unit, when viewed from the rear. To replace 
the water pressure switch, perform the procedure in Table 55.
Figure 53. View of Water Pressure Switch
Table 54
Step
Action
1
Disconnect power to the unit
2
Remove the appropriate side panel.
3
Turn off the syrup supply to the unit.
4
Drain the syrup from the system.
5
Disconnect the wires on the pressure switch.
6
Remove the switch, using two wrenches.
7
Replace the switch with a new unit.
8
Reverse the procedure to install the new switch.
9
Restore the syrup supply and check for leaks.
10
Check switch operation.
Syrup
Pressure
Switch
Water
Pressure
Switch