Applicative notes
Terminals command channel with Modbus reference channel
LO+
LO-
COM
LI1
LI2
LI3
LI4
LI2
LI3
LI4
+24
COM
AI1
5V
AO1
AI1
5V
AO1
R1A
R1B
R1C
R1B
R1C
R
S
T
U
PA+ PC-
PO
V
W
MODBUS
Note: Please refer to Function compatibility table page
.
1. Connect the ground terminal to the grounding screws located below the output
terminals.
2. Connect the power terminals.
3. Connect the logic input LI1 and plug RJ45 cable to the Modbus socket.
4. Turn on the drive without giving a run command.
5. Assign factory settings to the drive,
set to
InI.
6. Set the motor parameters (in COnF mode) only if the factory configuration of the
drive is not suitable.
7. Perform an auto-tuning.
page
to
SEP
.
page
Mdb
.
Check that
page
is set to
tEr
.
9. Start
ConF
CHCF
SEP
CtL-
ConF
Fr1
Mdb
CtL-
ConF
Cd1
tEr
CtL-
(a)
(a): Run Forward