4-03                                                                                                                 3                                                                                                       480-1081
North Star 
EPA Certified Fireplace
WARNING!
This  fireplace  and  its  components  are  designed  to  be 
installed  and  operated  as  a  system. Any  alteration  to 
or  substitution  for  items  in  this  system, unless  allowed 
by  these  installation  instructions,  will  void  the  OMNI 
Test Laboratories, Inc., listing and may void the product 
warranty. It may also create a hazardous installation. Read 
through  these  instructions  thoroughly  before  starting 
your  installation  and  follow  them  carefully  throughout 
your project.
1.    The fireplace system consists of the following:
a.    Fireplace
b.   Firebrick
c.    Chimney Termination Cap
d.   Chimney System
e.   Hearth Extension
f.    Outside Air
2.    Required Components Include:
a.    Chimney Air Kit
3.    Optional Components Include:
a.    Fire Screen
b.    Lintel Bar
c.    Heat Zone Kit
NOTE: Illustrations  used  throughout  these  instructions 
reflect “typical installations” and are for design purposes 
only.  Actual installation may vary slightly due to individual 
design preferences. However, minimum clearances must 
be maintained at all times.
The  illustrations  and  diagrams  used  throughout  these 
installation instructions are not drawn to scale.
Figure 3A - Typical Fireplace System
B. DESCRIPTION OF THE FIREPLACE 
SYSTEM
A.  LISTINGS AND CODE APPROVALS
This  fireplace  system  has  been  tested  and  listed  in 
accordance  with  UL127  and  ULC-S610-M87  standards, 
and  has  been  listed  by  OMNI Test  Laboratories,  Inc.,  for 
installation and operation in the United States and Canada 
as described in this manual.  The North Star Fireplace is 
approved for mobile home installations when not installed in 
a sleeping room and when an outside combustion air inlet 
is provided.  The structural integrity of the mobile home floor, 
ceiling, and walls must be maintained.  The fireplace must be 
properly grounded to the frame of the mobile home.  Outside 
Air must be installed in a mobile home installation. 
This fireplace has been tested and listed for use with the 
SL-300  Series  chimney  and  fireplace  components  listed 
on page 7. 
Check with your local building code agency before you begin 
your  installation  to  ensure  compliance  with  local  codes, 
including the need for permits and follow-up inspections.  Be 
sure local building codes do not supersede UL specifications 
and  always  obtain  a  building  permit  so  that  insurance 
protection benefits cannot be unexpectedly cancelled.
If  you  need  assistance  during  installation,  please  contact 
your local dealer.  For the number of your nearest Heat-N-Glo 
dealer, please call 1-888-427-3973.
Heat-N-Glo® is a registered trademark of Hearth & Home 
Technologies, Division of HON INDUSTRIES.