Hearth & Home Technologies 823-0290 사용자 설명서

다운로드
페이지 32
R
Page 16
  September 1, 2008
Isle Royale Wood Stove
250-5763C
Spark Arestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop
Listed Chimney 
Connector
Floor Protector
Outside Air Kit Connector
Outside Air Floor Vent
1
.  An outside air inlet must be provided for combustion and must remain 
clear of leaves, debris, ice and/or snow. It must be unrestricted while 
stove is in use to prevent room air starvation which can cause smoke 
spillage and an inability to maintain a fire.  Smoke spillage can also 
set off smoke alarms.
2.  Stove must be secured to the mobile home structure.  Use 1/4 inch 
(6mm) lag bolts with the appropriate length for your installation to secure 
stove through pad and into floor.
3.  Stove  must  be  grounded  with  #8  solid  copper  grounding  wire 
or  equivalent  and  terminated  at  each  end  with  N.E.C.  approved 
grounding device.
4.  Stove  must  be  installed  with  an  approved  UL103  HT  ventilated 
chimney connector, UL103 HT chimney, and terminal cap with spark 
arrestor. Never use a single wall connector (stove pipe) in a mobile 
home installation.  Use only double-wall connector pipe, Dura-Vent 
DVL, Selkirk metalbestos DS, Security DL double wall connector or 
any listed double wall pipe connector.
5. 
Refer to page 6 of this manual or the Serial Number label on the 
back of the stove for clearances to combustibles.
6.  Floor  protections  requirements  on 
page  7  must  be  followed 
precisely.
7.  In Canada, this appliance must be connected to a 6 inch (152mm) 
factory-built chimney conforming to CAN/ULC-629M, STANDARD 
FOR FACTORY BUILT CHIMNEYS. Floor protection referenced on 
page 7 must be followed.
8.  Use  silicone  to  create  an  effective  vapor  barrier  at  the  location 
where the chimney or other component penetrates to the exterior 
of the structure.
9.  Follow the chimney and chimney connector manufacturer’s instructions 
when installing the flue system for use in a mobile home.
NOTE:    Offsets  from  the  vertical,  not  exceeding  45°,  are  allowed  per 
Section  905(a)  of  the  Uniform  Mechanical  Code  (UMC).  Offsets 
greater  than  45°  are  considered  horizontal  and  are  also  allowed, 
providing  the  horizontal  run  does  not  exceed  75%  of  the  vertical 
height  of  the  vent.  Construction,  clearance  and  termination  must 
be  in  compliance  with  the  UMC Table  9C. This  installation  also 
complies with NFPA 211.
MOBILE HOME INSTALLATION
WARNING: NEVER DRAW COMBUSTION AIR 
FROM A WALL, FLOOR OR CEILING CAVITY 
OR FROM ANY ENCLOSED SPACE SUCH AS 
AN ATTIC OR GARAGE.
CAUTION:  THE  STRUCTURAL  INTEGRITY 
OF  THE  MOBILE  HOME  FLOOR,  WALL AND 
CEILING/ROOF  MUST  BE  MAINTAINED.  (i.e., 
DO NOT CUT THROUGH FLOOR JOIST, WALL 
STUD, CEILING TRUSS, ETC.)
WARNING: DO NOT INSTALL
 IN SLEEPING ROOM.
You must use a Quadra-Fire Outside Air Kit Part 831-1780 for installation in a mobile home.
NOTE: Top sections of chimney must be removable to allow maximum clearance of 13.5 ft. (411cm) from ground level for 
transportation purposes.
10.  Burn wood only.  Other types of fuels may generate poisonous gases (e.g., carbon monoxide).
11  If unit burns poorly while exhaust blower is on in home, (i.e. kitchen range hood) increase combustion air.