RECOMMENDATIONS FOR PROPER PROTECTION
 
The Following Recommendations for the Location of Fire and Burglary Detection 
Devices Help Provide Proper Coverage for the Protected Premises. 
 
Recommendations For Smoke And Heat Detectors 
With regard to the number and placement of smoke/heat detectors, we subscribe to the 
recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted 
below. 
Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms 
and areas of the household as follows: For minimum protection a smoke detector should be installed 
outside of each separate sleeping area, and on each additional floor of a multi-floor family living unit, 
including basements. The installation of smoke detectors in kitchens, attics (finished or unfinished), or 
in garages is not normally recommended. 
 
For additional protection the NFPA recommends that you install heat or smoke detectors in the living 
room, dining room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility and storage rooms, 
basements and attached garages. 
In addition, we recommend the following: 
•  Install a smoke detector inside every bedroom where a smoker sleeps. 
•  Install a smoke detector inside every bedroom where someone sleeps with the door partly or 
completely closed. Smoke could be blocked by the closed door. Also, an alarm in the hallway outside 
may not wake up the sleeper if the door is closed. 
 
 
DINING
KITCHEN
BEDROOM
BEDROOM
BEDROOM
BEDROOM
LIVING ROOM
BEDROOM
BDRM
BDRM
DINING 
LIVING ROOM
TV ROOM
KITCHEN
BEDROOM
BEDROOM
TO
BR
LVNG RM
BASEMENT
KTCHN
.
CLOSED
DOOR
GARAGE
Smoke Detectors for Minimum Protection
Smoke Detectors for Additional Protection
Heat-Activated Detectors
floor_plan-001-V0
 
 
•  Install a smoke detector inside bedrooms 
where electrical appliances (such as 
portable heaters, air conditioners or 
humidifiers) are used. 
•  Install a smoke detector at both ends of a 
hallway if the hallway is more than 40 
feet (12 meters) long. 
•  Install smoke detectors in any room where 
an alarm control is located, or in any room 
where alarm control connections to an AC 
source or phone lines are made. If 
detectors are not so located, a fire within 
the room could prevent the control from 
reporting a fire or an intrusion. 
 
THIS CONTROL COMPLIES WITH NFPA 
REQUIREMENTS FOR TEMPORAL PULSE 
SOUNDING OF FIRE NOTIFICATION 
APPLIANCES. 
 
 
 
Recommendations For Proper Intrusion Protection 
For proper intrusion coverage, sensors should be located at every possible point of entry to a home or 
commercial premises. This would include any skylights that may be present, and the upper windows 
in a multi-level building. 
In addition, we recommend that radio backup be used in a security system so that alarm signals can 
still be sent to the alarm monitoring station in the event that the telephone lines are out of order 
(alarm signals are normally sent over the phone lines, if connected to an alarm monitoring station).  