3com 8807 참조 가이드

다운로드
페이지 1099
64
C
HAPTER
 2: C
OMMANDS
 U
SED
 
TO
 L
OG
 
IN
 
TO
 S
WITCH
user-interface
Syntax
user-interface [ type ] first-number [ last-number ]
View
System view
Parameter
type: Specifies the user interface type, which can be aux, console or vty.
first-number: Specifies the number of the first user interface to be configured. It 
must be an integer in the range of 0 to 6.
last-number: Specifies the number of the last user interface to be configured. It 
must be an integer in the range of 1 to 6 and it must be greater than the value of 
first-number.
Description
Use the user-interface command to enter single user interface view to configure 
the corresponding user interfaces.
Example
# Enter vty 0 user interface view for configuration.
<SW8800>system-view
 
System View: return to User View with Ctrl+Z.
 
[SW8800] user-interface vty 0
 
[3Com-ui-vty0] 
user privilege level
Syntax
user privilege level level
undo user privilege level
View
User interface view
Parameter
level: Specifies which level of command a user can use after login from the 
specifically user interface, ranging from 0 to 3.
Description
Use the user privilege level command to configure which level of command a 
user can use after login from the specifically user interface, so that a user can use 
all the available commands at this level.
Use the undo user privilege level command to restore the default level of 
command a user can use after login from the specifically user interface.
By default, a user can access the commands at Level 3 after logging in through the 
Console user interface, and the commands at Level 0 after logging in through the 
AUX or VTY user interface.