3com 8807 참조 가이드

다운로드
페이지 1099
989
up-value: Upper temperature limit, in the range 20 to 90 °C.
Description
Use the temperature-limit command to configure temperature limit.
Use the undo temperature-limit command to restore temperature limit to 
default value.
Example
# Set the lower and upper temperature limit of card 0.
<SW8800> temperature-limit 0 10 75 
update l3plus
Syntax
update l3plus slot slot-no filename file-name ftpserver server-name 
username user-name password password [ port port-num ]
View
System view
Parameter
slot-no: Slot for the service processing module to be updated.
file-name: Name of upgrading file to be downloaded. The file suffix is .app.
server-name: IP address or host name of FTP Server where the file to be updated 
locates.
user-name: User name for file transfer protocol (FTP) login.
password: User password for FTP login.
port-num: FTP port number, in the range 0 to 65,535. By default, it is 21.
Description
Use the update l3plus command to update service processing modules. After the 
command is executed, the system logs into an FTP Server with the host name, user 
name and user password provided. The system downloads the host software 
containing load program of service processing module to the system’s synchronous 
dynamic random access memory (SDRAM), and uses the file to enable service 
processing modules.
CAUTION:
When you use the update l3plus command to update service processing 
modules, you must use the switch host APP file which includes the load 
program of L3PLUS service processing modules.
The maximum size of L3PLUS update file loaded by the update l3plus 
command is 24 M.