3com 8807 참조 가이드

다운로드
페이지 1099
122
C
HAPTER
 9: GARP&GVRP C
ONFIGURATION
 C
OMMANDS
Parameter
interface-list: List of Ethernet ports of which the GRRP timer information is to be 
displayed, expressed as interface-list = { interface-type interface-number [ to 
interface-type interface-number ] }&<1-10>. interface-type is interface type, and 
interface-number is interface number. The interface number after the keyword to 
must be larger than or equal to that before to. &<1-10> means that the preceding 
parameter can be repeated up to 10 times.
Description
Use the display garp timer command to view the value of GARP timer, including 
Hold timer, Join timer, Leave timer and LeaveAll timer.
Related command: garp timergarp timer leaveall.
Example
# Display GARP timer on Ethernet2/1/1.
<SW8800> display garp timer interface ethernet2/1/1
 
      GARP timers on port Ethernet2/1/1
 
                GARP JoinTime           : 20 centiseconds
 
                GARP Leave Time         : 60 centiseconds
 
                GARP LeaveAll Time       : 1000 centiseconds
 
                GARP Hold Time          : 10 centiseconds 
garp timer
Syntax
garp timer { hold | join | leave } timer-value
undo garp timer { hold | join | leave }
View
Ethernet port view
Parameter
hold: GARP Hold timer. After receiving certain registration information, the GARP 
application entity will not send Join Message at once. Instead, it starts the Hold 
timer. All the registration information received within duration of the Hold timer 
will be transmitted in the same frame after the Hold timer times out, thereby 
saving the bandwidth resource.
join: GARP Join timer. GARP application entity will send out Join message after the 
Join timer goes timeout to make other GARP application entity register its own 
information.
leave: GARP Leave timer . When a GARP application entity wants to deregister 
certain attribute information, it sends Leave message. The GARP application entity 
receiving the message starts Leave timer. If the entity receives no Join message 
before the timer goes timeout, it will deregister the attribute information.
timer-value: Value of GARP hold timer, join timer and leave timer in centiseconds. 
The step is five centiseconds. By default, Hold timer is 10 centiseconds, Join timer 
is 20 centiseconds, Leave timer is 60 centiseconds.
The range conforms to the following rule: