Juniper JX-1E3-S 데이터 시트

다운로드
페이지 4
2
Specifications
Product Specifications
Dimensions and Weight (W x H x D)
•  5.45 x 0.63 x 6.5 in (13.8 x 1.6 x 16.5 cm)
Network Interface Specifications
•  High-Level Data Link Control (HDLC) features
 
- Shared flag
 
- Idle flag/fill (0x7e or all ones)
 
- Counters:  runts, giants, frame check sequence (fcs) error, 
abort error, align error
 
- Maximum transmission unit (MTU):  Normal (4500 bytes) or 
Jumbo (max 9192 bytes)
•  Subrate and scrambling support for major DSU vendors:
 
- DS3:  Verilink, Kentrox, Digital Link, Larscom, Adtran
 
- E3:  Digital Link, Kentrox
•  Interface connector:  DSX3 interface with dual female 75-ohm 
BNC coaxial connectors (separate Rx/Tx)
•  System timing:  Internal, LoopData interface
Environmental
•  Operating temperature:  0° to 40° C
•  Storage temperature:  -40° to 70° C
•  Relative humidity:  5 to 90% noncondensing
Diagnostics
Loopbacks
•  DS3:  Local, remote, payload
•  E3:  Local, remote  
Test Patterns (BERT)
•  All ones
•  All zeros
•  Alternating ones and zeros (AA/55)
•  PRBS 2^15-1 (as specified in ITU-T O.151)
•  PRBS 2^20-1 (as specified in ITU-T O.153)
•  QRSS 2^20-1 (as specified in ITU-T O.151)
•  PRBS 2^23-1 (as specified in ITU-T O.151)
•  PRBS 2^9-1
•  PRBS 2^11-1
•  PRBS 2^29-1
•  PRBS 2^31-1
Note:  E3 BERT support available in unframed mode only
Network Alarms
•  DS3 alarms in conformance with the ANSI specification:
 
- Loss of signal (LOS)
 
- Out of frame (OOF)
 
- Loss of frame (LOF)
 
- Alarm indication signal (AIS)
 
- Remote defect indication (RDI)
•  E3 alarms in conformance with the ITU-T specification:
 
- Loss of signal (LOS)
 
- Out of frame (OOF) (for framed mode only)
 
- Alarm indication signal (AIS)
 
- Remote defect indication (RDI) (for framed mode only)
 
- Phase-locked loop (PLL) alarm
Error Counters (DS3/E3)
•  Line code violations (LCV)
•  P-bit code violations (PCV)
•  C-bit code violations (CCV)
•  Line errored seconds (LES)
•  P-bit errored seconds (PES)
•  C-bit errored seconds (CES)
•  Severely errored framing seconds (SEFS)
•  P-bit severely errored seconds (PSES)
•  C-bit severely errored seconds (CSES)
•  Unavailable seconds (UAS)
•  C-bit coding violations-far end (CCV-FE) [FEBE]
•  C-bit errored seconds-far end (CES-FE)
•  Unavailable seconds-far end (UAS-FE)
•  Error Counters (E3 only):
 
- Frame alignment error (FAE)
 
- Bipolar coding violations (BCV)
 
- Excessive zeros (EXZ)
 
- Line code violations (LCV)
 
- Line errored seconds (LES)
 
- Severely errored framing seconds (SEFS)
 
- Unavailable seconds (UAS)
LEDs
PIM LEDs indicate port status with the following LED states:
Color  
State  
 
Description
Green  
On steadily  
Online with no alarms or failures. 
Red  
On steadily  
Active with a local alarm; router has    
 
 
 
detected a failure. 
Yellow  On steadily  
Remote RDI/yellow alarm