Juniper JX-1E3-S 데이터 시트
2
Specifications
Product Specifications
Dimensions and Weight (W x H x D)
• 5.45 x 0.63 x 6.5 in (13.8 x 1.6 x 16.5 cm)
Network Interface Specifications
• High-Level Data Link Control (HDLC) features
- Shared flag
- Idle flag/fill (0x7e or all ones)
- Counters: runts, giants, frame check sequence (fcs) error,
abort error, align error
- Maximum transmission unit (MTU): Normal (4500 bytes) or
Jumbo (max 9192 bytes)
• Subrate and scrambling support for major DSU vendors:
- DS3: Verilink, Kentrox, Digital Link, Larscom, Adtran
- E3: Digital Link, Kentrox
• Interface connector: DSX3 interface with dual female 75-ohm
BNC coaxial connectors (separate Rx/Tx)
• System timing: Internal, LoopData interface
Environmental
• Operating temperature: 0° to 40° C
• Storage temperature: -40° to 70° C
• Relative humidity: 5 to 90% noncondensing
Diagnostics
Loopbacks
• DS3: Local, remote, payload
• E3: Local, remote
Test Patterns (BERT)
• All ones
• All zeros
• Alternating ones and zeros (AA/55)
• PRBS 2^15-1 (as specified in ITU-T O.151)
• PRBS 2^20-1 (as specified in ITU-T O.153)
• QRSS 2^20-1 (as specified in ITU-T O.151)
• PRBS 2^23-1 (as specified in ITU-T O.151)
• PRBS 2^9-1
• PRBS 2^11-1
• PRBS 2^29-1
• PRBS 2^31-1
Note: E3 BERT support available in unframed mode only
Note: E3 BERT support available in unframed mode only
Network Alarms
• DS3 alarms in conformance with the ANSI specification:
- Loss of signal (LOS)
- Out of frame (OOF)
- Loss of frame (LOF)
- Alarm indication signal (AIS)
- Remote defect indication (RDI)
• E3 alarms in conformance with the ITU-T specification:
- Loss of signal (LOS)
- Out of frame (OOF) (for framed mode only)
- Alarm indication signal (AIS)
- Remote defect indication (RDI) (for framed mode only)
- Phase-locked loop (PLL) alarm
Error Counters (DS3/E3)
• Line code violations (LCV)
• P-bit code violations (PCV)
• C-bit code violations (CCV)
• Line errored seconds (LES)
• P-bit errored seconds (PES)
• C-bit errored seconds (CES)
• Severely errored framing seconds (SEFS)
• P-bit severely errored seconds (PSES)
• C-bit severely errored seconds (CSES)
• Unavailable seconds (UAS)
• C-bit coding violations-far end (CCV-FE) [FEBE]
• C-bit errored seconds-far end (CES-FE)
• Unavailable seconds-far end (UAS-FE)
• Error Counters (E3 only):
- Frame alignment error (FAE)
- Bipolar coding violations (BCV)
- Excessive zeros (EXZ)
- Line code violations (LCV)
- Line errored seconds (LES)
- Severely errored framing seconds (SEFS)
- Unavailable seconds (UAS)
LEDs
PIM LEDs indicate port status with the following LED states:
Color
State
Description
Green
On steadily
Online with no alarms or failures.
Red
On steadily
Active with a local alarm; router has
detected a failure.
Yellow On steadily
Remote RDI/yellow alarm