LG M3204CCBA 사용자 설명서

다운로드
페이지 93
Controlling Multiple Set 
RS-232C
A1
Controlling the Multiple Product
RS-232C
A1
A1
Connecting the cable
Connect the RS-232C cable as shown in the picture.
  You need to purchase a cable to connect the RS-232C socket as it is not provided as the 
accessory.
The RS-232C protocol is used for communication between the PC and product. You can 
turn the product on/off, select an input source or adjust the OSD menu from your PC.
Use this method to connect several products to a single PC. You can control several products at a 
time by connecting them to a single PC. 
If the [Set ID] menu in [Option] is set to OFF, the monitor ID value should be set between 1 and 99.
RS-232C Cable
(not included)
monitor 1
PC
monitor 2
monitor 3
monitor 4
7-Wire Configurations (Standard RS-232C cable)
RXD
TXD
GND
DTR
DSR
RTS
CTS
TXDRXD
GND
DSR
DTR
CTS
RTS
PC 
    Monitor
2
3
5
4
6
7
8
3
2
5
6
4
8
7
 D-Sub 9               D-Sub 9 
(Female)               (Female)   
3-Wire Configurations (Not Standard)
RXD
TXD
GND
DTR
DSR
RTS
CTS
TXDRXD
GND
DTR
DSR
RTS
CTS
PC 
    Monitor
2
3
5
4
6
7
8
3
2
5
6
4
7
8
 D-Sub 9               D-Sub 9 
(Female)               (Female)   
► Baud Rate : 9600 buad Rate (UART)
► Data Length : 8 bit
► Parity Bit : None
► Stop Bit : 1bit
► Flow Control : None
► Communication Code : ASCII code
► Use a crossed (reverse) cable
Communication Parameter
RS-232C Configurations