KitchenAid 30" Range Hood with the FIT System 사용 및 관리

다운로드
페이지 24
5
Installation Clearances
Venting Requirements
These range hoods are factory set for non-vented 
(recirculating) installations and come with a charcoal filter. 
See the “Assistance or Service” section for information 
on ordering a charcoal filter kit, Part Number W10355450.
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 
70 (latest edition) or CSA Standards C22.1-94, Canadian 
Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition), 
and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that 
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association 
1 Batterymarch Park 
Quincy, MA 02169-7471
CSA International 
8501 East Pleasant Valley Road 
Cleveland, OH 44131-5575
 
A 120 volt, 60 Hz., AC only, 15-amp, fused 
electrical circuit is required.
 
If the house has aluminum wiring, follow 
the procedure below:
1.  Connect a section of solid copper wire 
to the pigtail leads.
2.  Connect the aluminum wiring to the added section 
of copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended 
procedure. Aluminum/copper connection must conform 
with local codes and industry accepted wiring practices.
 
Wire sizes and connections must conform with the rating 
of the appliance as specified on the model/serial/rating 
plate. The model/serial/rating plate is located inside the 
range hood on the left wall.
 
Wire sizes must conform to the requirements of the National 
Electrical Code, ANSI/NFPA 70 (latest edition) or CSA 
Standards C22. 1-94, Canadian Electrical Code, Part 1 
and C22.2 No. 0-M91 (latest edition), and all local codes 
and ordinances.
B
A
C
D
E
A.  24" (61 cm) minimum distance from electric cooking surface 
24" (61 cm) minimum distance from gas cooking surface 
30" (76.2 cm) suggested maximum above the cooking surface
B.  18" (45.7 cm) minimum clearance - upper cabinet to countertop
C.  30" (76.2 cm) minimum cabinet opening width for 30" 
(76.2 cm) models and 36" (91.4 cm) minimum cabinet 
width for 36" (91.4 cm) models
D.  12" (30.5 cm) cabinet depth
E.  36" (91.4 cm) base cabinet height