KitchenAid 30" Range Hood with the FIT System 설치 가이드

다운로드
페이지 28
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting 
installation. Read and follow the instructions provided 
with any tools listed here.
Tools needed
Parts supplied
Remove parts from package. Check that all parts are included.
Parts needed
For 3
1
/
4
" x 10" (8.3 x 25.4 cm) rectangular vented 
installations
Optional accessories
 * For information on ordering, see the “Assistance or Service” 
section.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
 
It is the installer’s responsibility to comply with installation 
clearances specified on the model/serial/rating plate. 
The model/serial/rating plate is located inside the range 
hood on the left wall.
 
Range hood location should be away from strong draft 
areas, such as windows, doors, and strong heating vents.
 
Cabinet opening dimensions that are shown must be 
used. Given dimensions provide minimum clearance. 
Consult the cooktop/range manufacturer installation 
instructions before making any cutouts.
 
This range hood is recommended for use with cooktops 
with a maximum total rating of 40,000 BTUs or less.
 
Grounded electrical outlet is required. See “Electrical 
Requirements” section.
 
All openings in ceiling and wall where range hood will 
be installed must be sealed.
 
These range hoods are factory set for vented installations. 
Models that are capable of being installed as non-vented 
(recirculating) require charcoal filters. See the “Assistance or 
Service” section for information on ordering charcoal filters.
For Mobile Home Installations
The installation of this range hood must conform to the 
Manufactured Home Construction Safety Standards, Title 
24 CFR, Part 328 (formerly the Federal Standard for Mobile 
Home Construction and Safety, title 24, HUD, Part 280), 
or when such standard is not applicable, the standard for 
Manufactured Home Installation 1982 (Manufactured Home 
Sites, Communities and Setups) ANSI A225.1/NFPA 501A 
or latest edition, or with local codes.
Product Dimensions
Caulking gun and weatherproof
caulking compound
Jigsaw or keyhole saw
Flat-blade
screwdriver
Drill with ¹⁄₈" 
(3 mm), ¹⁄₂" 
(13 mm)
and 1¹⁄₄" 
(3 cm) bits
Wire stripper
#2 Phillips
screwdriver
Metal snips
Pencil
3¹⁄₄" x 10" (8.3 x 25.4 cm)
rectangular damper
#8-18 x ⁵⁄₈" 
(4.2 x 16 mm)
truss-head screws
#8-18 x 1"
(4.2 x 25 mm) 
flat-head screws
Drywall
anchors
Mounting
brackets
UL Listed/CSA 
Approved 
wire connectors
UL Listed/CSA 
Approved ¹⁄₂" (13 mm) 
strain relief
120V, 75W 
maximum, 
type E26 
incandescent lamp
3¹⁄₄" x 10" 
(8.3 x 25.4 cm) rectangular 
metal vent system with
wall or roof cap
Duct tape
Power 
cord kit 
Part Number
W10355452*
Stainless steel cleaner 
and polish 
Part Number 31462A*
1" 
(2.5 cm)
4¹⁵⁄₁₆" 
(12.5 cm)
6⁹⁄₁₆" (16.7 cm)
 
29¹⁵⁄₁₆" (76.0 cm)
 
18⁵⁄₈" 
(47.3 cm)
 1¹⁄₂
(3.8 cm)
9" 
(22.9 cm)
2" 
(5.1 cm)
1" 