Bosch KGE 39 AI 20 R 사용자 설명서

다운로드
페이지 70
en
20
Appliance self-test
Your appliance features an automatic 
self-test program which shows you 
sources of faults which may be repaired 
by customer service only.
Starting the appliance self-test
1. Switch off the appliance and wait 
5 minutes.
2. Switch on the appliance and within the 
first 10 seconds hold down a super 
button, Fig.
2/8 or 10, for 
5-10 seconds until the second 
warning signal sounds.
The self-test programme starts.
When the self-test ends and a warning 
signal sounds twice, your appliance is in 
working order.
If the alarm button
2/5 flashes and 
5 acoustic signals sound, there is a fault. 
Inform customer service.
Ending the appliance self-test
When the programme has ended, the 
appliance switches over to normal 
operation.
Fault
Possible cause
Remedial action
Freezer compartment 
temperature display 
flashes. Fig.
2/3
Warning signal sounds
The Alarm button is lit. 
Fig.
2/5
The freezer 
compartment is too 
warm! 
The frozen food 
is at risk of thawing!
To switch off the warning signal, 
press the Alarm button 5. 
Appliance is open.
Close the appliance.
Ventilation openings 
have been covered.
Ensure that there is adequate 
ventilation.
Too much food was 
placed in the freezer 
compartment at once.
Do not exceed max. freezing 
capacity.
When the fault has been eliminated, 
the Alarm display goes out shortly 
afterwards.
Freezer compartment 
temperature display 
flashes. Fig.
2/3
A fault  caused 
the freezer 
compartment 
to become too warm 
in the past.
When the alarm button 5 is pressed, 
the temperature display stops 
flashing. Fig.
2/3 
The temperature display indicates 
for 5 seconds the warmest 
temperature which was reached 
in the freezer compartment.