Cisco Cisco Firepower 4120 Security Appliance 정보 가이드
Cisco FXOS Compatibility
4
ASA Clustering External Hardware Support
The following table lists supported external hardware and software for inter-chassis clustering. For intra-chassis
clustering, the Firepower 9300 chassis can operate with any switch because the chassis-to-switch connections
use standard interface types. See the FXOS configuration guide for logical device support for inter-chassis
clustering.
clustering, the Firepower 9300 chassis can operate with any switch because the chassis-to-switch connections
use standard interface types. See the FXOS configuration guide for logical device support for inter-chassis
clustering.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To
view a list of Cisco trademarks, go to this URL:
view a list of Cisco trademarks, go to this URL:
. Third-party trademarks mentioned are the property
of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other
company. (1110R)
company. (1110R)
© 2015-2016 Cisco Systems, Inc. All rights reserved.
Table 6
ASA Clustering External Hardware Support
External Hardware
External Software
FXOS Version
Cisco ASR 9000 with RSP 440
Cisco IOS XR 5.3(1) and later
1.1.3 and later
Cisco Nexus 9500
Cisco NX-OS 6.1(2)I2(1) and later
1.1.3 and later
Cisco Nexus 9300
Cisco NX-OS 6.1(2)I2(1) and later
1.1.3 and later
Cisco Nexus 7000
Note: You can use F1-series line cards for the
cluster control link, but we do not recommend using
them for data Spanned Ether Channels due to
asymmetric load-balancing, which can cause
performance degradation for data throughput on the
cluster.
cluster control link, but we do not recommend using
them for data Spanned Ether Channels due to
asymmetric load-balancing, which can cause
performance degradation for data throughput on the
cluster.
Cisco NX-OS 5.2(5) and later
1.1.3 and later
Cisco Nexus 6000
Cisco NX-OS 7.0(2)N1(1) and later
1.1.3 and later
Cisco Nexus 5000
Cisco NX-OS 7.0(1) and later
1.1.3 and later
Catalyst 6800 with Supervisor 2T
Cisco IOS 15.1(2)SY5 and later
1.1.3 and later
Catalyst 6500 with Supervisor 32, 720, and
720-10GE
720-10GE
Cisco IOS 12.2(33)SXI7, SXI8, and SXI9 and
later
later
1.1.3 and later
Catalyst 6500 with Supervisor 2T
Cisco IOS 15.1(2)SY5 and later
1.1.3 and later
Catalyst 4500-X
Note: You can use this switch for the cluster control
link, but we do not recommend using this switch for
data Spanned EtherChannels due to asymmetric
load-balancing, which can cause performance
degradation for data throughput on the cluster.
link, but we do not recommend using this switch for
data Spanned EtherChannels due to asymmetric
load-balancing, which can cause performance
degradation for data throughput on the cluster.
Cisco IOS 3.6(3) and later
1.1(3.86) and
later
later
Catalyst 4500 with Supervisor 8-E
Cisco IOS XE 3.7.1E and later
1.1.3 and later
Catalyst 3850
Note: You can use this switch for the cluster control
link, but we do not recommend using this switch for
data Spanned EtherChannels due to asymmetric
load-balancing, which can cause performance
degradation for data throughput on the cluster.
link, but we do not recommend using this switch for
data Spanned EtherChannels due to asymmetric
load-balancing, which can cause performance
degradation for data throughput on the cluster.
Cisco IOS 3.7(3) and later
1.1(3.86) and
later
later
Catalyst 3750-X
Cisco IOS 15.0(2) and later
1.1.3 and later