Alarms / Traps
Warm Start
Link Up/Down
Chassis Insertion/Removal
Authentication Failure
DIP-Switch Configuration Change
Software Configuration Change
Temperature Out-of-Range
Power Supply Out-of-Range
Power Supply Insertion/Removal
Chassis Reset
Module Reset
Module Insertion/Removal
Port Link State Change
Redundancy Primary Up/Down
Redundancy Secondary Up/Down
FTP Session Open/Close
Telnet Session Open/Close
Dying Gasp (Power Loss Trap)
Active Controls
Link Propagate/Link Segment
Remote Fault Detection
Module Name
Chassis Name and Number
IP Address
802.3ah OAM Enable
Secure IP-less OAM Enable
Subnet Mask
Gateway
Management Port Disable
Alarm Threshold Setting
Download Software via FTP
Reset Chassis
Telnet
Trap IPs
FTP Enable
Password Selection
Soft Switch Reload
IP-less management requires an NMM in the core chassis, and
a media converter with integrated management installed at each
remote end of the IP-less managed link.  An iConverter
 
10/100M2
plug-in module is installed in the 19-Module chassis, and
connected via the fiber link to a standalone 10/100M2 Network
Interface Device (NID). This configuration enables the 19-Module
master chassis to establish an IP-less management channel
between the 10/100M2 link partners. The IP address
resides only at the network core, and does not exist on the
customer network.
Model
Description
8000-0
iConverter NMM Module w/ Dying Gasp Support
8080-3
NMM Cascade Cable (3 ft.)
8081-3
NMM Serial Cable (DB-9, 3 ft.)
 Model  Type
NMM
 Protocols
IP, UDP, SNMPv1, SNMPv2c, SNMPv3,
Telnet, TCP, FTP, ARP, ICMP, 802.3ah
 Connectors
RJ-45, DB-9
 Controls
UTP cross-over, Frontplane / Backplane
 LED Displays
Power, Power Supply (3), UTP link,
Master, Slave, Mgt. Poll
 Supported MIBs
RFC1155, RFC1156, RFC1157,
RFC1212, RFC1213, OST MIB
 Dimensions
W:0.85" x D:4.5" x H:2.8"
 Weight
8 oz.
 Compliance
UL, CE, FCC Class A, NEBS 3
 Power Requirement
0.32A @ 3.3VDC (typical)
 Temperature
Standard:       0 to 50º C
Wide:          -40 to 60º C
Storage:      -40 to 80º C
 Humidity
5 to 95% (non-condensing)
 Altitude
-100m to 4000m
 MTBF (hrs)
786,000
Chassis Information
Part Number
Serial Number
Revision
Description
Chassis Status
Power Status
Power Output Voltage
Chassis Temperature
Module Status
Module Power
Link Status
Active Port
Diagnostic Status
Management
Module Information
Module Type
Slot Occupied
Part Number
Serial Number
Configuration
Revision
Ports on Module
User-defined Identifier