DKS Enterprises 1803PC 사용자 설명서

다운로드
페이지 67
6.1.4  Elevator Board / Floor Hardware Test 
This testing sequence will allow you to check activation of individual relays on the elevator control 
board(s) and will confirm communication between the telephone entry system circuit board and the 
elevator control board(s). 
 
1.  Press *77 and enter the four-digit master code _ _ _ _ (beep). 
 
The display will show:  WHICH ELEVATOR? (1815 - 1817 systems only). 
2.  Enter the elevator shaft number (1, 2, 3 or 4) _ , then press * (beep). 
 
The display will show:  FLOOR? (1815 - 1817 systems only). 
3.  Enter the two-digit floor number _ _ , then press * (beep). 
4.  The relay LED on the elevator control board that represents the floor number entered will 
turn ON for approximately 1 second. 
5.  To check other floor relays, repeat steps 2 and 3. 
6.  When complete with the testing, press 0# TOGETHER to end this testing sequence. 
NOTE:  This program test sequence will automatically end itself if no keypad inputs are 
detected after approximately 30 seconds. 
 
Refer to the Elevator Control board installation manual for more information on trouble 
shooting the elevator control boards

 
 
 
63