Intel 82543GC 사용자 설명서

다운로드
페이지 24
82543GC Gigabit Ethernet Controller Specification Update 
 
 
 
 
13
Implication:  
Data transfer performance is substantially reduced due to error packets. 
Workaround:  
None.   
Status:  
Intel resolved this erratum in the A1 stepping of the 82543GC Gigabit Ethernet Controller. 
8.  48 Bit Preambles Sent in 10Mb and 100Mb Operation 
 
Problem:   
The 82543GC device transmits 48 bit preambles instead of 56 bit preambles for 10Mb and 100Mb operation. 
Implication:  
Certain 10Mb and 100Mb repeaters will only tolerate 56 bit preambles, so packets transmitted by the 82543GC 
controller will be incompatible. A product example is the Intel InBusiness 4 Port Fast Hub, which is based on a 
Broadcom 5205 repeater device. 
Workaround:  None. 
Status:  
Intel resolved this erratum in the A1 stepping of the 82543GC Gigabit Ethernet Controller. 
9.  CRS Detection Takes Too Long in MII Half-Duplex Mode 
 
Problem:  
When the 82543GC controller is operated in half-duplex mode, it can take up to 16 bit times to detect Carrier 
Sense (CRS) assertion. 
Implication:  
The IEEE specification is 8 bit times. Functional problems are not anticipated in operating networks, however. 
Workaround:  None. 
Status:  
Intel resolved this erratum in the A1 stepping of the 82543GC Gigabit Ethernet Controller. 
10. DMA Early Receive Function Does Not Work 
 
Problem:   
When DMA early receive operation is enabled on the 82543GC device and a DMA receive underrun occurs, the 
controller may erroneously place data into the packet descriptors. 
Implication:  
The early receive function cannot be used. 
Workaround:  None. 
Status:  
Intel does not plan to resolve this erratum in a future stepping of the 82543GC Gigabit Ethernet Controller. 
11. ILOS Bit Copied Incorrectly from EEPROM to Speed Bits 
 
Problem:  
When the 82543GC controller loads configuration information from EEPROM, it maps the Invert Loss of Signal 
(ILOS) bit into the Speed Selection bits in the device control register.  
Implication:  
Both the ILOS and Speed settings will be incorrect. 
Workaround:  
Software should write correct bit values into the control register. 
Status:  
Intel resolved this erratum in the A1 stepping of the 82543GC Gigabit Ethernet Controller. 
12. Gigabit Half-Duplex Mode Operates Incorrectly 
 
Problem:  
Several problems prevent proper gigabit half-duplex operation. 
Implication:  