                                                                          R&D / Automotive Electronics
 
Title 
Remote Keyless Entry System Specification 
Spec. No. 
DPE-AE-RK019912S 
Written by  
Ban Dong Hoon 
Rev. No.  
A0 
Date 10
th
 . Nov. 2003 
Page 
11 / 25
 
 
3.4   
SAFETY LOCK(AUTO DOOR LOCK AFTER 30SEC) 
At the arming mode, if the door / trunk / hood open and the ignition on is not occurred during 30 
seconds after all door is unlocked by the Tx unlock button or the Tx door button, then all door is 
locked again and the Rx also goes to the arming mode. At the case of the safety lock, even 
though the Rx goes to the arming mode, the EEPROM data of the Rx about alarm is not changed. 
If the remote door unlock is actuated again during the waiting time (30 seconds), the safety lock 
process is restarted. 
 
3.5  
SECURITY INDICATOR 
If the Rx status enters to the arming mode, the security indicator is blinking period 1sec (0.12sec 
ON 0.88sec OFF). 
 
Security Indicator 
RKE & ATAS Status 
Blinking(f=1Hz) Duty cycle 1:7(ON/OFF)  Arming, Trunk Rearming State 
OFF Disarming 
Status 
[Table 3. Security Indicator Operating timing Chart] 
 
3.6                 DIAGNOSTIC 
Communication between the ECU and the diagnostic tester takes place in accordance with 
ISO9141-2, with line K only but without line L. Line K is a bidirectional data line used to convey 
request messages from the diagnostic tester to the ECU and response messages from the ECU to 
the diagnostic tester. Additional DIAGNOSTIC function refers to the document 
SPECIFICATION #DPE-AE-RK509603S Keyless Entry System Diagnostic Specification. 
 
3.7                 ACTIVE RANGE 
Active functions of the receiver shall be operable when the Tx is with in the specified range of 
the vehicle, as follows: 
 
FUNCTION RANGE 
All functions 
≥10m : Ignition OFF 
≥ 6m : Ignition OB 
[Table 4. Active Range]