Daewoo Precision Industries Ltd RK950NAR 사용자 설명서
R&D / Automotive Electronics
Title
Remote Keyless Entry System Specification
Spec. No.
DPE-AE-RK019912S
Written by
Ban Dong Hoon
Rev. No.
A0
Date 10
th
. Nov. 2003
Page
17 / 25
5.
SYSTEM INPUT/OUTPUT CIRCUIT
5.1.1 SERIAL DATA LINK(NO. A17)
It is the line for communicate receiver and diagnostic device. It defines RKE diagnostic protocol
regulation(#DPE-AE-RK509603S)
It is the line for communicate receiver and diagnostic device. It defines RKE diagnostic protocol
regulation(#DPE-AE-RK509603S)
5.1.2 ELECTRIC OUTPUT
5.1.2.1 HAZARD LAMP (LEFT : A26, RIGHT : A13)
- Type
: Normal open Relay
(V23072-C1061-A408)
- Output Level
: Battery voltage to GND
- Max. switching current
: 2 x 60 A
- Max. continuous current
: 2 x 10 A @ +23℃
- Fault Diagnostic Request
: No
- State During Reset
: Off
- Short Circuit Protection Request : No
- Over Current Protection Request
- Over Current Protection Request
: No
- RIGHT LOAD : 21W x 2EA, 5W x 1EA
- LEFT LOAD : 21W x 2EA, 5W x 1EA
- LEFT LOAD : 21W x 2EA, 5W x 1EA
5.1.2.2 SECURITY INDICATOR(A19)
-
Type
:
Low
Side
Drive
- Output Level
: 1V to GND
- Max. Output Current
: 100mA
- Min./Max. Duty Cycle
: 0 / 100 %
- Fault Diagnostic Request
: No
- State During Reset
: Off
- Short Circuit Protection Request : No
- Over Current Protection Request
- Over Current Protection Request
: Yes
5.1.2.3 LOCK(A10)
- Type
: Low Side Drive
- Max. Low Output Level
: 1V to GND
- Max. Output Current
: 500mA
- Fault Diagnostic Request
: No
- State During Reset
: Off
- Short Circuit Protection Request
: Yes
- Over Current Protection Request
: Yes
5.1.2.4 UNLOCK(A11)
- Type
: Low Side Drive