TE Connectivity Blade terminal Connector width: 6.3 mm Connector thickness: 0.8 mm 180 ° Insulated Blue 3-520107-2 1 pc 3-520107-2 데이터 시트
제품 코드
3-520107-2
108-2043
3.3.
Ratings
!
Voltage: 600 volts AC m axim um
!
Operating Tem perature: 105°C m axim um
3.4.
Perform ance and Test Description
Product is designed to m eet the electrical, m echanical and environm ental perform ance requirem ents
specified in Figure 1.
specified in Figure 1.
3.5.
Test Requirem ents and Procedures Sum m ary
Test Description
Requirem ent
Procedure
Exam ination of Product.
Meets requirem ents of product
drawing and Application Spec 114-
2123.
drawing and Application Spec 114-
2123.
TE Spec 109-1.
Visual, dim ensional and functional
per applicable inspection plan.
Visual, dim ensional and functional
per applicable inspection plan.
ELECTRICAL
Dielectric W ithstanding Voltage,
Test Condition A.
Test Condition A.
No breakdown or flashover when
3400 volts AC are applied for 1
m inute.
3400 volts AC are applied for 1
m inute.
UL 310, 600 Volt Rating.
Test wired term inals in Num ber 12
lead shot.
Test wired term inals in Num ber 12
lead shot.
Dielectric W ithstanding Voltage,
Test Condition C.
Test Condition C.
No breakdown or flashover at rear
of term inal when 3000 volts AC are
applied for 1 m inute.
of term inal when 3000 volts AC are
applied for 1 m inute.
UL 310, 600 Volt Rating.
Test on flat m etal plate.
See Figure 4.
Test on flat m etal plate.
See Figure 4.
Dielectric W ithstanding Voltage,
Receptacle, Tab Entry Position.
Receptacle, Tab Entry Position.
Term inal Applied
Size Voltage (volts AC)
250 1000
187 1000
110 600
No breakdown or flashover, 1
m inute hold.
Size Voltage (volts AC)
250 1000
187 1000
110 600
No breakdown or flashover, 1
m inute hold.
TE Spec 109-29-1.
Test wired term inals on a flat m etal
plate.
See Figure 5.
Test wired term inals on a flat m etal
plate.
See Figure 5.
Heating (Tem perature Rise).
W ire Size Current (am peres)
(AW G) .110 Others
26 1 1
24 2 2
22 2 3
20 3 4
18 4 7
16 5 10
14 8 15
12 – 20
10 – 24
20°C m axim um tem perature rise.
(AW G) .110 Others
26 1 1
24 2 2
22 2 3
20 3 4
18 4 7
16 5 10
14 8 15
12 – 20
10 – 24
20°C m axim um tem perature rise.
UL 310.
Stabilize at specified current and
m easure tem perature rise.
Stabilize at specified current and
m easure tem perature rise.
Figure 1 (continued)
Rev D
2 of 5