Futaba Hendheld RC 2.4 GHz No. of channels: 14 1-F8075 데이터 시트

제품 코드
1-F8075
다운로드
페이지 168
129
<Model Menu (Airplane/Glider Functions)>
● Select the function name 
and return to the Model 
menu by touching the 
R T N   b u t t o n .   O r   t h e 
H O M E / E X I T   b u t t o n   i s 
pushed.
<SensorTouch™>
RETURN
ELE to CAMBER
[Corresponding model type]: Airplane/glider, 2 ailerons or more
This function is used when you want to mix the 
camber flaps with elevator operation. When used,  
the flaps are lowered by up elevator, and lift is 
increased.
● In-flight mixing can be turned ON/OFF by assigning 
this to a switch. (Always ON at [--] setting)
● The mixing rate can be adjusted.
● The point that has little effect near the neutral 
position of the elevator stick can be adjusted. 
(Glider only)
Note: The elevator on the tailless wing will also 
be effected when this mix is activated.
●Mixing rate adjustment
  Move the cursor to the up or down mixing 
rate item for each servo and touch the RTN 
button to switch to the data input mode. 
Adjust the rate independently by scrolling 
the touch sensor. 
  Initial value: 0%
  Adjustment range: -100~+100%
*When the RTN button is touched for one second, the rate is 
reset to the initial value.)
  Touch the RTN button to end the adjustment 
and return to the cursor mode.
Setting method
●Activate the function
  Move the cursor to the [ACT] item and touch 
the RTN button to switch to the data input 
mode. Select the ACT mode by scrolling the 
touch sensor. 
*The display blinks.
  Touch the RTN button to activate the 
function and return to the cursor mode. (ON 
is displayed.)
  When setting a switch, move the cursor to 
the [SW] item and touch the RTN button to 
call the selection screen. Select the switch 
and set its ON direction. (Always ON at "--" 
setting)
*For a description of the switch selection method, see the 
description at the back of this manual.
●Range setting (Glider only)
  Move the cursor to the [RANGE] item and 
hold the elevator stick to the desired position 
(upper or lower side) and then touch the RTN 
button for one second to set the range. 
*The mixing does not work near neutral of the  elevator stick.
  Initial value: 0%
  Adjustment range: 0~100%
(Glider: Currently selected condition name)
● Select [ELE to CAMBER] at the Model 
menu and access the setup screen 
shown below by touching the RTN 
button.
*The display screen is an example. 
The actual screen depends on the 
model type.
Scrolling
● Moving cursor
● Selecting mode
● Adjusting value
● To next page