Easy to communicate between devices 
 
7.5 PROFINET 
 
Easy Book 
136
 
Manual, 03/2014, A5E02486774-AF 
The following example shows the communication between two CPUs that utilize 1 
connection for both sending and receiving the data.  
●  Each CPU uses a TCON instruction to configure the connection between the two CPUs. 
●  The TSEND instruction in CPU_1 links to the TRCV instruction in CPU_2 by using the 
connection ID ("connection ID 1") that was configured by the TCON instruction in CPU_1. 
The TRCV instruction in CPU_2 links to the TSEND instruction in CPU_1 by using the 
connection ID ("connection ID 1") that was configured by the TCON instruction in CPU_2. 
●  The TSEND instruction in CPU_2 links to the TRCV instruction in CPU_1 by using the 
connection ID ("connection ID 1") that was configured by the TCON instruction in CPU_2. 
The TRCV instruction in CPU_1 links to the TSEND instruction in CPU_2 by using the 
connection ID ("connection ID 1") that was configured by the TCON instruction in CPU_1. 
 
 
  TCON on CPU_1 creates a 
connection and assigns a connection 
ID for that connection on CPU_1 
(ID=1). 
  TCON on CPU_2 creates a 
connection and assigns a connection 
ID for that connection on CPU_2 
(ID=1). 
  TSEND and TRCV on CPU_1 use the 
connection ID created by the TCON 
on CPU_1 (ID=1). 
TSEND and TRCV on CPU_2 use the 
connection ID created by the TCON 
on CPU_2 (ID=1).